hydraulic hose fitting,hose fittings,hydraulic adapters In the hydraulic system, both the metal pipe fitting, hose fitting, or are prone to leakage problems. deformation caused by leaks, you should check whether the card sets out of round, edge or without defects, whether the pipe ends in good condition and the extent of compression ferrule nut, but also eliminate the pipeline force.
2013年8月29日星期四
hydraulic coupling gear failure causes
Large power station boiler feed pump hydraulic coupling gear shaft sudden rupture during operation , which is why, below you analyze .First, a large hydraulic coupling on the broken shaft gear usage , the chemical composition of the steel , high and low times , umbrella -phase structure , grain size , mechanical properties and fracture surface of Hydraulic adaptersreal axis of the macro view of fracture for fracture , and Wei the observation and detection and analysis .Secondly, the analysis of large gear shaft of the production process and the use of profiles , using optical microscopy, scanning electron microscopy , transmission electron microscopy and X- ray spectrometer to observe and analyze the failure of the shaft fracture.
订阅:
博文评论 (Atom)
没有评论:
发表评论