hydraulic hose fitting,hose fittings,hydraulic adapters In the hydraulic system, both the metal pipe fitting, hose fitting, or are prone to leakage problems. deformation caused by leaks, you should check whether the card sets out of round, edge or without defects, whether the pipe ends in good condition and the extent of compression ferrule nut, but also eliminate the pipeline force.
2013年9月8日星期日
Liquid Rubber bet irrigation water hydraulic hydraulic test Operational Details
Liquid Rubber bet especially for water drainage system and sub- stratified horizontal pipe riser hydraulic test rigor , but also for sanitary ware and floor drain rigor hydraulic test . Hydraulic test should be used for special plugging inflators , airbag shutoff specifications shall be hydraulically tested pipeline facilities. Hydraulic test procedures as follows:( 1 ) Preparation: First inflator combination of accessories for leak testing and inspection tool . The balloon is placed in a bucket filled with water and hold a pump to the air bag inflates , check the air bags, hoses , and interface leaks , gauges without instructions.( 2 ) with a tape measure from the mouth to the floor riser inspection horizontal tube below the minimum vertical distance and extended 500 mm ( length 2m), remember this length and this length is marked on the hose connected to the airbag and airbag on , make mark to control the balloon inserted into the riser depth.( 3 ) open riser inspection port , the balloon slowly from the mouth down into to the desired length, then the air bag inflates , observe the pressure gauge value , the pointer rises to 0.08 ~ 0.1MPa appropriate, the airbag in close contact with the tube wall Tuen water did not leak for the degree. If the inspection port is designed to install a spacer layer , the riser is not set checkpoints floors irrigation pipe hydraulic test , the airbag should be checked from the lower riser up into the mouth of approximately 0.5m, operating personnel in the lower inflation , the upper irrigation . Note that the airbag should be avoided on the stand pipe pieces joints because the site wall seams , affecting water shutoff rigor. For Hydraulic tube fittings cast iron pipes , requiring sand clean, smooth wall , not allowed to have glitches, otherwise it will affect the water shutoff seal, even punctured balloon .( 4 ) in the floor of the irrigation port ( You can also check the mouth ) irrigation -to-floor height, and then on the irrigation pipes and pipe fittings interfaces each inspection , if found tainted point , make a mark , drainage repair after treatment ; such as liquid rubber Hydraulic adapters Hydraulic adapters ring flexible interface , the interface can be leak tight bolt restoration with water . Such as irrigation pipeline inspection without a leakage point, the water level can stabilize the irrigation time duration 15 minutes , keeping five minutes irrigation level does not drop as qualified.( 5 ) the balloon deflated , and then slowly pull out the capsule , be careful not to damage the capsule .( 6 ) Remove the airbag , the water should be able to quickly drain away , such as falling very slowly , indicating that irrigation pipe clogged with debris , should be cleaned up.( 7 ) with the balloon inflated method can also check for leaks squat stool . Placed in the bladder outlet squat stool and inflated , and then squat stool inside irrigation ( water level toilet along ) , if the water level dropped , indicating a leak rinse water interface , or squat stool water interfaces closed lax, or squat stool leakage itself , should be directed excluded .( 8 ) irrigation hydraulic test should partition segment ( layer ) for the hydraulic test results should be recorded .( 9 ) buried pipeline irrigation hydraulic test method is basically the same
订阅:
博文评论 (Atom)
没有评论:
发表评论